The biggest advantage of 3D printed orthotics over milled EVA is that we can engineer stiffness independently of shape. With EVA, stiffness is set by material density and shell thickness. With MJF nylon, we tune stiffness through internal lattice geometry — so a 3mm rigid shell and a 3mm flexible shell can have the same external dimensions but very different mechanical behaviour.
The flex index
At Motion X we use a 1–5 flex index on every 3D printed shell:
- Flex 1 (soft): Comparable to 4mm Polypropylene. Maximum compliance, minimum correction. Pediatric, accommodative, AFO-style scripts.
- Flex 2 (medium-soft): The “comfort” default. Patients with osteoarthritis, fragile structures, or who have failed in stiffer orthotics.
- Flex 3 (standard): The everyday default. Most adult prescriptions, general orthotics, casual sports.
- Flex 4 (firm): Active patients, runners, court sport, hyperpronators needing more resistance.
- Flex 5 (rigid): Maximum control. Severe pes planus, posterior tibial tendon dysfunction stage II–III, neurological tone management.
Why flex index beats material thickness
In traditional orthotics, “stiffer” meant “thicker”, which meant “bulkier and heavier”. With 3D printed lattices we increase wall density and add internal supports without increasing external dimensions. A Flex 5 shell can be the same 3mm profile as a Flex 1 shell — but four times stiffer.
Matching flex to patient
The most common prescribing mistake is going too rigid. A Flex 5 shell on a patient with reasonable foot mobility creates a foreign-body feel and patients abandon the orthotic. As a rule of thumb:
- Body weight under 60kg → reduce one flex level from your usual choice
- Body weight over 100kg → increase one flex level
- High-impact sport → increase one flex level
- Failed previous orthotics due to “too hard” → decrease one flex level
How to specify
The flex index is on the standard prescription form in My Orthotic App. Default is Flex 3. Specify by patient name and we will print to that index. We can mix flex levels left/right if a patient has asymmetric needs. Contact the lab for unusual cases — we have built shells with variable flex (rigid medial, flexible lateral) for specific neurological presentations.