We process hundreds of prescriptions a month at Motion X. Most are excellent. A small but consistent percentage have the same five issues. Here are the mistakes we catch most often, and how to avoid them — so the orthotic does what you want first time.

1. Specifying the patient’s diagnosis instead of the orthotic build

“Plantar fasciitis” is not a build instruction — it is a problem to solve. Two patients with plantar fasciitis can need radically different orthotics depending on rearfoot eversion, fat pad atrophy, calf flexibility and footwear. Tell us the build (Flex 3, 14mm cup, 4mm medial skive, A-TPU cover) and we will print exactly that. If you tell us the diagnosis, we have to guess at the build — and your guess is better than ours.

2. Over-specifying skive depth

Skive is one of those numbers that scales worse than linearly. 6mm of skive is not 1.5× as effective as 4mm — it is 3× more aggressive in patient feel. Most patients with moderate pronation do well at 4mm. The most common over-prescription we see is 6mm skive on patients who would do better at 4mm. Start moderate, increase only on follow-up.

3. Forgetting the shoe

The orthotic has to fit in something. We routinely receive scripts with 16mm heel cups for patients in dress flats, or 4mm forefoot wedges for football boots. Always check shoe volume before specifying. If the shoe is the constraint (slim dress, running flats, court sport), tell us — we have slim builds optimised for low-volume footwear.

4. Mismatched correction and material

A Flex 5 rigid shell with a 4mm medial heel skive in a soft cushion patient creates a foreign-body feel that drives non-compliance. The correction needs to match the patient’s tolerance. If the patient has failed in stiffer orthotics, drop a flex level even if biomechanics suggest more rigidity. If the patient is heavy and active, increase a flex level even if biomechanics suggest medium.

5. Skipping the top cover detail

Top cover material has more day-to-day impact on patient experience than almost any biomechanical decision. EVA, A-TPU, M-PEBA7, M-TPU12, Invigr8 and Poron all feel completely different. If you leave the top cover field blank we default to 3mm EVA — fine for most, wrong for some. Specify the top cover that matches the patient (performance, comfort, lightweight, accommodative).

How the lab fixes them

We flag any prescription that looks contradictory and email the practitioner before printing. If you would prefer we just build what is written, tell us in the notes field. Contact the lab any time — pre-build review is free and saves remakes.